close



  

 

 

Login

Our Clients

Who's online

We have 4 guests online
Ulti Clocks content
PDF Print E-mail
PRODUCT DESCRIPTION
Heavy Duty
Industrial Temperature Sensor
with solid drilled flanged thermowell 
Many areas of process plant demand temperature sensors with a
rugged construction to meet both the demands of the process and
the installation environment. A thermowell machined from solid bar
stock offers a higher integrity for those more demanding process parameters
and a flanged process connection enables it’s use in higher
process pressures. The choice of connection head type and extension
also allows a specification to be drawn up that will satisfy most requirements.
S P E C I F I C A T I O N
Thermowell 
Materials :304, 316 or 310 stainless steel, Hastelloy C, Monel,
Nickel 200, Titanium.
Process connection :minimum flange size ½” ANSI 150 RF, but BS, metric
and flanges to JIS standards are also available.
Lagging extension :½” NB pipe plain extension or ½” NB nipple/union/
nipple in carbon steel, galvanised or 316 stainless
steel.
Connection head :in die-cast aluminium with screw cap, retention
chain and M20 cable entry or ½” NPT conduit connection.
Environmental rating to IP67.
Spring loaded insert 
Sheath :321, 316L or 310 stainless steel, 6mm OD (length to
suit thermowell) and fitted with a spring loaded ceramic
terminal block.
Resistance Thermometer 
Detector :single or duplex PT100 with 3 wire connection ,
Class ‘B’ or ‘A’ tolerance and to BS EN 60751:1996.
Operating range :-50 to +380°C (-58 to+716°F)
Thermocouple 
Element :single, duplex or triplex elements, types ‘T’ (Cu/
Con), ‘E’ (NiCr/Con), ‘J’ (Fe/Con) ‘K’ (NiCr/NiAl) or
‘N’ (Nicrosil/Nisil) to BS EN 60584-1:1996.
Operating range :-50 to +850°C (-58 to+1562°F), depending on
thermocouple type.
A temperature transmitter with a 4 to 20mA output can be supplied in place
of the connection block for both hazardous and non-hazardous duties. Other
dimensions and tolerances outside the above specifications may also be
available on application.